Chapter 5 ONLINE HELP SOPAS
LECTOR®620
160 © SICK AG · Germany · All rights reserved · Subject to change without notice 8013778/Y269/2013-11-27
Parameters
5.10.13.5.5 Control
The Control parameter is used to choose between configuration with units of length or con-
figuration with units of time.
• T
RACK CONTROLLED: The entries for the Length parameter are made in mm.
• T
IME CONTROLLED: The entries for the Length parameter are made in ms.
5.10.13.5.6 Length
If the T
IMER/TRACKING condition is selected under the Function (Off) parameter, you can use
the Length parameter to enter the duration for which the digital output remains activated.
The unit can be selected in the Control parameter.
5.10.13.6 External output 2
The number of available digital outputs can be expanded via the CDB620/CDM420 connec-
tion module in conjunction with the CMC600 parameter memory module. The purpose of
the CMC parameter memory module is to expand the output and convert a digital signal into
a command. External digital outputs generally respond more slowly than the internal digital
outputs of the LECTOR
®
620.
The External output 2 group contains the parameters for adjusting external digital output 2.
5.10.13.6.1 Active
The Active parameter is used to select the event for which the digital output is activated.
• SOPAS C
OMMAND: The output is activated by a command. As a result, the defined statuses
can be displayed via a connected control lamp as a result of a controller (PLC) command.
• D
EVICE READY: The output is activated as soon as the LECTOR
®
620 is operational.
• G
OOD READ: The output is activated in the event of a successful reading.
• N
O READ: The output is activated in the event of an unsuccessful reading.
• T
EACH-IN 1 OK: The output is activated if the MATCHCODE TEACH-IN 1 was taught in suc-
cessfully.
• T
EACH-IN 1 NOK: The output is activated if the MATCHCODE TEACH-IN 1 was not taught in suc-
cessfully.
• T
EACH-IN 2 OK: The output is activated if the MATCHCODE TEACH-IN 2 was taught in suc-
cessfully.
• T
EACH-IN 2 NOK: The output is activated if the MATCHCODE TEACH-IN 2 was not taught in suc-
cessfully.
• C
ONDITION MATCH 1: The output is activated if the read code corresponds to the matchcode
from C
ONDITION MATCH 1.
• C
ONDITION MULTCODES1: The output is activated if the number of read codes corresponds
to the required number from C
ONDITION MULTCODES1.
• C
ONDITION TEACHIN1: The output is activated if the read code corresponds to the match-
code from C
ONDITION TEACHIN1.
• C
ONDITION TEACHIN2: The output is activated if the read code corresponds to the match-
code from C
ONDITION TEACHIN2.