5.7.14.2.5 Fixed length 4
A fixed symbol size can be selected using the Fixed length 4 parameter. Only codes with this
symbol size are read.
Defining specific permissible symbol sizes restricts the spectrum of codes to be read. This
can lead to a reduction in the decoding time.
5.7.14.2.6 Fixed length 5
A fixed symbol size can be selected using the Fixed length 5 parameter. Only codes with
this symbol size are read.
Defining specific permissible symbol sizes restricts the spectrum of codes to be read. This
can lead to a reduction in the decoding time.
5.7.14.2.7 Allow rectangular data fields
If the Symbol size parameter has value F
REE , square (e.g. 16 x 16) and rectangular (e.g. 8
x 18) symbols are identified if the Allow rectangular data fields parameter is activated.
5.7.14.3 Reducing evaluation time
The decoding time is adapted to the application on site and optimized via the parameters
for the Reducing evaluation time group.
5.7.14.3.1 Code surrounded by patterns
If the Code surrounded by patterns parameter is activated, patterns/lines (e.g. strip conduc-
tors on printed circuit board) in the code environment are ignored during evaluation.
As a result, the reading concentrates on the code elements and the decoding time is redu-
ced.
Codes with poor quality are generally ignored if the function is activated.
5.7.14.3.2 Code surrounded by text
If the Code surrounded by text parameter is activated, text (e.g. on packaging) in the code
environment are ignored during evaluation.